105℃ 600V PVC Insulation Wire
105℃ 600V PVC INSULATION WIRE. Rated temperature: 105℃. Rated voltage: 600V. According to: UL 758, UL1581, CSA C22.2. Solid or Stranded, tinned or bare copper conductor 20-10AWG. PVC insulation. Passes UL VW-1 & CSA FT1 Vertical flame test. Application: Internal wiring of appliances or electronic equipment ( ).
| UL1056 | (AWG) Gauge (AWG): 20 · conductor Construction (no/mm): 26/0.16 · (mm) Conductor outer Diameter (mm): 0.94 · (mm) Insulation Thickness (mm): 1.53 · (mm) Wire O.D (mm): 4.1±0.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 36.7 · Standard pup-up FT/ROLL: 2000 · METER/ROLL: 610 |
|---|---|
| Standard | UL758, UL1581, CSA C22.2 |
| UL1056 (2) | (AWG) Gauge (AWG): 18 · conductor Construction (no/mm): 16/0.254 · (mm) Conductor outer Diameter (mm): 1.17 · (mm) Insulation Thickness (mm): 1.53 · (mm) Wire O.D (mm): 4.3±0.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 23.2 · Standard pup-up FT/ROLL: 2000 · METER/ROLL: 610 |
| UL1056 (3) | (AWG) Gauge (AWG): 16 · conductor Construction (no/mm): 26/0.254 · (mm) Conductor outer Diameter (mm): 1.49 · (mm) Insulation Thickness (mm): 1.53 · (mm) Wire O.D (mm): 4.65±0.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.6 · Standard pup-up FT/ROLL: 2000 · METER/ROLL: 610 |
| UL1056 (4) | (AWG) Gauge (AWG): 14 · conductor Construction (no/mm): 41/0.254 · (mm) Conductor outer Diameter (mm): 1.87 · (mm) Insulation Thickness (mm): 1.53 · (mm) Wire O.D (mm): 5.05±0.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 8.96 · Standard pup-up FT/ROLL: 2000 · METER/ROLL: 610 |
| UL1056 (5) | (AWG) Gauge (AWG): 12 · conductor Construction (no/mm): 65/0.254 · (mm) Conductor outer Diameter (mm): 2.36 · (mm) Insulation Thickness (mm): 1.53 · (mm) Wire O.D (mm): 5.7±0.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 5.64 · Standard pup-up FT/ROLL: 2000 · METER/ROLL: 610 |
| UL1056 (6) | (AWG) Gauge (AWG): 10 · conductor Construction (no/mm): 105/0.254 · (mm) Conductor outer Diameter (mm): 3.0 · (mm) Insulation Thickness (mm): 1.53 · (mm) Wire O.D (mm): 6.3±0.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 3.546 · Standard pup-up FT/ROLL: 2000 · METER/ROLL: 610 |
| Construction | Solid or Stranded, tinned or bare copper conductor 20-10AWG; PVC insulation |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing