60℃ 75℃ 90℃ 105℃ 300V PVC Flexible Power Cords Cable
60℃ 75℃ 90℃ 105℃ 300V PVC Flexible Power Cords Cable. Rated temperature: 60℃, 75℃, 90℃, 105℃. Rated voltage: 300V. According to: UL 62, UL1581. Stranded bare copper conductor 20-18AWG (as printed). PVC insulation. Passes UL VW-1 & CSA FT1 Vertical flame test. Application: Power supply cord of electronic equipment.
| SPT-3 | Gauge (AWG): 18 · conductor Construction (no/mm): 41/0.16 · Conductor outer Diameter (mm): 1.18 · Grounging Wire NO.: 2 · Insulation Thickness (mm): 1.52 · Wire O.D (mm): 4.5×9.0 · Max Cond Resistance (Ω/km,20℃): 21.8 |
|---|---|
| Standard | UL 62, UL1581 |
| SPT-3 (2) | Gauge (AWG): 18 · conductor Construction (no/mm): 41/0.16 · Conductor outer Diameter (mm): 1.18 · Grounging Wire NO.: 3 · Grounging Wire O.D.(mm): 2.0 · Insulation Thickness (mm): 1.52 · Wire O.D (mm): 4.5×10.34 · Max Cond Resistance (Ω/km,20℃): 21.8 |
| SPT-3 (3) | Gauge (AWG): 16 · conductor Construction (no/mm): 26/0.254 · Conductor outer Diameter (mm): 1.49 · Grounging Wire NO.: 2 · Insulation Thickness (mm): 1.52 · Wire O.D (mm): 4.8×9.6 · Max Cond Resistance (Ω/km,20℃): 13.7 |
| SPT-3 (4) | Gauge (AWG): 16 · conductor Construction (no/mm): 26/0.254 · Conductor outer Diameter (mm): 1.49 · Grounging Wire NO.: 3 · Grounging Wire O.D.(mm): 2.3 · Insulation Thickness (mm): 1.52 · Wire O.D (mm): 4.8×11.2 · Max Cond Resistance (Ω/km,20℃): 13.7 |
| SPT-3 (5) | Gauge (AWG): 14 · conductor Construction (no/mm): 41/0.254 · Conductor outer Diameter (mm): 1.88 · Grounging Wire NO.: 2 · Insulation Thickness (mm): 2.03 · Wire O.D (mm): 6.3×12.6 · Max Cond Resistance (Ω/km,20℃): 8.62 |
| SPT-3 (6) | Gauge (AWG): 14 · conductor Construction (no/mm): 41/0.254 · Conductor outer Diameter (mm): 1.88 · Grounging Wire NO.: 3 · Grounging Wire O.D.(mm): 2.7 · Insulation Thickness (mm): 2.03 · Wire O.D (mm): 6.3×13.5 · Max Cond Resistance (Ω/km,20℃): 8.62 |
| SPT-3 (7) | Gauge (AWG): 12 · conductor Construction (no/mm): 65/0.254 · Conductor outer Diameter (mm): 2.36 · Grounging Wire NO.: 2 · Insulation Thickness (mm): 2.41 · Wire O.D (mm): 7.6×15.2 · Max Cond Resistance (Ω/km,20℃): 5.43 |
| SPT-3 (8) | Gauge (AWG): 12 · conductor Construction (no/mm): 65/0.254 · Conductor outer Diameter (mm): 2.36 · Grounging Wire NO.: 3 · Grounging Wire O.D.(mm): 3.2 · Insulation Thickness (mm): 2.41 · Wire O.D (mm): 7.6×16.8 · Max Cond Resistance (Ω/km,20℃): 5.43 |
| SPT-3 (9) | Gauge (AWG): 10 · conductor Construction (no/mm): 105/0.254 · Conductor outer Diameter (mm): 3.0 · Grounging Wire NO.: 2 · Insulation Thickness (mm): 2.79 · Wire O.D (mm): 9.1×18.2 · Max Cond Resistance (Ω/km,20℃): 3.4 |
| SPT-3 (10) | Gauge (AWG): 10 · conductor Construction (no/mm): 105/0.254 · Conductor outer Diameter (mm): 3.0 · Grounging Wire NO.: 3 · Grounging Wire O.D.(mm): 3.8 · Insulation Thickness (mm): 2.79 · Wire O.D (mm): 9.1×19.8 · Max Cond Resistance (Ω/km,20℃): 3.4 |
| Construction | Stranded bare copper conductor (catalog text states 20-18AWG; table covers 18-10AWG), PVC insulation; flat parallel cord, 2-conductor or 3-conductor with grounding wire |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing