Electric Cable (UL) For Battery Energy Storage System
ELECTRIC CABLE (UL) FOR BATTERY ENERGY STORAGE SYSTEM. Using temperature: -40℃~+105℃. Rated voltage: 2000V AC/2000V DC. Pass the test for FT4 of flame retardance. The belding radius not less than five times the cable 4xOD, easy to install. Note: The product's description please refer to the specification for approval. Note: rows printed as UL 11627 20WG and UL 11627 0AWG (apparent misprints for 20AWG and 2/0AWG; transcribed as printed). Application: Used for Battery Energy Storage System, battery connection, connection between battery and shunt box, flexible cable.
| Standard | UL758 |
|---|---|
| Construction | Conductor: Annealed soft tin copper; Insulation: 105℃ PVC (PVC ) |
| UL 11627 0AWG | conductor Construction (no/mm): 1330/0.254TS · Stranded Dia. (mm): 12.20 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.2766 · Nominal Thickness (mm): 2.04 · Insulation Dia. (mm): 16.5 |
| UL 11627 1AWG | conductor Construction (no/mm): 836/0.254TS · Stranded Dia. (mm): 9.53 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.4268 · Nominal Thickness (mm): 1.53 · Insulation Dia. (mm): 13.9 |
| UL 11627 20WG | conductor Construction (no/mm): 26/0.16TS · Stranded Dia. (mm): 0.94 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 36.7 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 2.6 |
| UL 11627 2AWG | conductor Construction (no/mm): 665/0.254TS · Stranded Dia. (mm): 9.15 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.5548 · Nominal Thickness (mm): 1.53 · Insulation Dia. (mm): 12.0 |
| UL 11627 4AWG | conductor Construction (no/mm): 420/0.254TS · Stranded Dia. (mm): 6.47 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.882 · Nominal Thickness (mm): 1.53 · Insulation Dia. (mm): 10.0 |
| UL 11627 6AWG | conductor Construction (no/mm): 266/0.254TS · Stranded Dia. (mm): 5.20 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 1.403 · Nominal Thickness (mm): 1.53 · Insulation Dia. (mm): 8.5 |
| UL 11627 8AWG | conductor Construction (no/mm): 168/0.254TS · Stranded Dia. (mm): 4.25 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 2.23 · Nominal Thickness (mm): 1.15 · Insulation Dia. (mm): 6.7 |
| UL 11627 10AWG | conductor Construction (no/mm): 105/0.254TS · Stranded Dia. (mm): 3.10 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 3.546 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 4.9 |
| UL 11627 12AWG | conductor Construction (no/mm): 65/0.254TS · Stranded Dia. (mm): 2.36 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 5.64 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 4.0 |
| UL 11627 14AWG | conductor Construction (no/mm): 41/0.254TS · Stranded Dia. (mm): 1.88 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 8.96 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 3.55 |
| UL 11627 16AWG | conductor Construction (no/mm): 26/0.254TS · Stranded Dia. (mm): 1.50 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 14.6 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 3.15 |
| UL 11627 18AWG | conductor Construction (no/mm): 41/0.16TS · Stranded Dia. (mm): 1.18 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 23.2 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 2.8 |
| UL 11627 22AWG | conductor Construction (no/mm): 17/0.16TS · Stranded Dia. (mm): 0.76 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 59.4 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 2.4 |
| UL 11627 24AWG | conductor Construction (no/mm): 11/0.16TS · Stranded Dia. (mm): 0.61 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 94.2 · Nominal Thickness (mm): 0.76 · Insulation Dia. (mm): 2.2 |
| UL 11627 1/0AWG | conductor Construction (no/mm): 1045/0.254TS · Stranded Dia. (mm): 11.10 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.3487 · Nominal Thickness (mm): 2.04 · Insulation Dia. (mm): 15.5 |
| UL 11627 3/0AWG | conductor Construction (no/mm): 1672/0.254TS · Stranded Dia. (mm): 13.71 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.2193 · Nominal Thickness (mm): 2.04 · Insulation Dia. (mm): 18.0 |
| UL 11627 4/0AWG | conductor Construction (no/mm): 2109/0.254TS · Stranded Dia. (mm): 14.70 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.1722 · Nominal Thickness (mm): 2.04 · Insulation Dia. (mm): 20.2 |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing