Electric Cable (TÜV) For Photovoltaics System
ELECTRIC CABLE (TÜV) FOR PHOTOVOLTAICS SYSTEM. Approvals: TÜV Rheinland 2pfg 1169 PV1-F 2×1.5mm2~16mm2 (Multiple color). Rated voltage: AC U0/U=1000/1000VAC, 1500VDC. Finished voltage withstand test: 6.5kV AC, 15kV DC, 5min. Ambient temperature: -40℃ up to +90℃. Conductor maximum temperature: +120℃. Service life: >25years (-40℃ up to +90℃).
| 2*10 | conductor Construction (no/mm): 84/0.4 · Insulation Ave.Thic. (mm): 0.70 · Sheath Ave.Thic. (mm): 0.80 · Cable outside diameter minimum outer diameter (mm): 7.50*15.20 · Max Cond Resistance (Ω/km,20℃): 1.95 · **Current carring Capacity AT 60℃ (A): 98 |
|---|---|
| 2*16 | conductor Construction (no/mm): 128/0.4 · Insulation Ave.Thic. (mm): 0.70 · Sheath Ave.Thic. (mm): 0.90 · Cable outside diameter minimum outer diameter (mm): 9.60*19.70 · Max Cond Resistance (Ω/km,20℃): 1.24 · **Current carring Capacity AT 60℃ (A): 132 |
| 2*1.5 | conductor Construction (no/mm): 30/0.25 · Insulation Ave.Thic. (mm): 0.70 · Sheath Ave.Thic. (mm): 0.80 · Cable outside diameter minimum outer diameter (mm): 5.00*10.30 · Max Cond Resistance (Ω/km,20℃): 13.7 · **Current carring Capacity AT 60℃ (A): 30 |
| 2*2.5 | conductor Construction (no/mm): 49/0.25 · Insulation Ave.Thic. (mm): 0.70 · Sheath Ave.Thic. (mm): 0.80 · Cable outside diameter minimum outer diameter (mm): 5.20*10.80 · Max Cond Resistance (Ω/km,20℃): 8.21 · **Current carring Capacity AT 60℃ (A): 41 |
| 2*4.0 | conductor Construction (no/mm): 56/0.285 · Insulation Ave.Thic. (mm): 0.70 · Sheath Ave.Thic. (mm): 0.80 · Cable outside diameter minimum outer diameter (mm): 5.50*11.20 · Max Cond Resistance (Ω/km,20℃): 5.09 · **Current carring Capacity AT 60℃ (A): 55 |
| 2*6.0 | conductor Construction (no/mm): 84/0.285 · Insulation Ave.Thic. (mm): 0.70 · Sheath Ave.Thic. (mm): 0.80 · Cable outside diameter minimum outer diameter (mm): 6.20*12.60 · Max Cond Resistance (Ω/km,20℃): 3.39 · **Current carring Capacity AT 60℃ (A): 70 |
| Standard | 2pfg 1169 |
| Construction | Conductor: Annealed soft tin copper (Tinner copper according to VDE0295/IEC60228, class 5); Insulation: Polyolefin copolymer electron-beam cross-linked; Outer sheath/Jacket: Polyolefin copolymer electron-beam cross-linked |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing