Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems. Using temperature: -40℃~+125℃; -40℃~+150℃. Rated voltage: 1000V DC. Halongen free, follow the environment-friendly product's developing direction. Pass the test for vertical flame propagation, high class of flame retardance. The belding radius not less than five times the cable 5xOD, easy to install. Application: Used for EV car battery high voltage system, Battery connection of Energy Storage System, flexible cable. The product's description please refer to the specification for approval.
| Standard | LV216-1 |
|---|---|
| Construction | Conductor: Annealed soft bare copper; Insulation: 125℃/150℃ thermosetting elastomers |
| EV-YJ/SIR 1X4mm² | conductor Construction (no/mm): 133/0.2AS · Stranded Dia. (mm): 2.66 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 4.71 · Nominal Thickness (mm): 0.80 · Insulation Dia. (mm): 4.3 |
| EV-YJ/SIR 1X6mm² | conductor Construction (no/mm): 190/0.2AS · Stranded Dia. (mm): 3.42 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 3.14 · Nominal Thickness (mm): 0.80 · Insulation Dia. (mm): 5.1 |
| EV-YJ/SIR 1X10mm² | conductor Construction (no/mm): 323/0.2AS · Stranded Dia. (mm): 4.40 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 1.82 · Nominal Thickness (mm): 1.00 · Insulation Dia. (mm): 6.5 |
| EV-YJ/SIR 1X16mm² | conductor Construction (no/mm): 513/0.2AS · Stranded Dia. (mm): 5.70 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 1.16 · Nominal Thickness (mm): 1.00 · Insulation Dia. (mm): 7.9 |
| EV-YJ/SIR 1X25mm² | conductor Construction (no/mm): 798/0.2AS · Stranded Dia. (mm): 6.70 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.743 · Nominal Thickness (mm): 1.30 · Insulation Dia. (mm): 9.6 |
| EV-YJ/SIR 1X35mm² | conductor Construction (no/mm): 1121/0.2AS · Stranded Dia. (mm): 8.00 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.527 · Nominal Thickness (mm): 1.30 · Insulation Dia. (mm): 10.6 |
| EV-YJ/SIR 1X50mm² | conductor Construction (no/mm): 1596/0.2AS · Stranded Dia. (mm): 9.50 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.368 · Nominal Thickness (mm): 1.50 · Insulation Dia. (mm): 12.50 |
| EV-YJ/SIR 1X70mm² | conductor Construction (no/mm): 2257/0.2AS · Stranded Dia. (mm): 11.50 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 0.259 · Nominal Thickness (mm): 1.50 · Insulation Dia. (mm): 14.50 |
| EV-YJ/SIR 1X2.5mm² | conductor Construction (no/mm): 136/0.15AS · Stranded Dia. (mm): 2.06 · 20℃ Conductor Max Resistance AT 20℃ (Ω/km): 7.60 · Nominal Thickness (mm): 0.70 · Insulation Dia. (mm): 3.5 |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

QZJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing