ELECTRIC CABLE (TÜV) FOR BATTERY ENERGY STORAGE SYSTEM. Using temperature: -40℃~+90℃. Rated voltage: 1000V DC. Pass the test for EN60332-1-2 vertical flame retardance ( EN60332-1-2 ). The belding radius not less than five times the cable4xOD, easy to install ( ≥4xOD ). Application: Used for Battery Energy Storage System, battery connection, connection between battery and shunt box, flexible cable ( ). The product's description please refer to the specification for approval.
| Standard | 2 PfG 2693/06.19 |
|---|---|
| Construction | conductor: Annealed soft bare copper or tinned copper ( ); insulation: PVC ( PVC ) |
| ESW10V2V2-K 1X4mm² | Conductor conductor Construction (no/mm): 133/0.2AS · Conductor Stranded Dia. (mm): 2.66 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 4.71 · Insulation Nominal Thickness (mm): 0.5/0.4 · Insulation MAX.Insulation Dia. (mm): 5.2 |
| ESW10V2V2-K 1X6mm² | Conductor conductor Construction (no/mm): 190/0.2AS · Conductor Stranded Dia. (mm): 3.42 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 3.14 · Insulation Nominal Thickness (mm): 0.5/0.6 · Insulation MAX.Insulation Dia. (mm): 6.2 |
| ESW10V2V2-K 1X10mm² | Conductor conductor Construction (no/mm): 323/0.2AS · Conductor Stranded Dia. (mm): 4.40 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 1.82 · Insulation Nominal Thickness (mm): 0.6/0.7 · Insulation MAX.Insulation Dia. (mm): 7.8 |
| ESW10V2V2-K 1X16mm² | Conductor conductor Construction (no/mm): 513/0.2AS · Conductor Stranded Dia. (mm): 5.70 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 1.16 · Insulation Nominal Thickness (mm): 0.7/0.8 · Insulation MAX.Insulation Dia. (mm): 9.6 |
| ESW10V2V2-K 1X25mm² | Conductor conductor Construction (no/mm): 798/0.2AS · Conductor Stranded Dia. (mm): 6.70 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 0.743 · Insulation Nominal Thickness (mm): 0.7/0.9 · Insulation MAX.Insulation Dia. (mm): 11.5 |
| ESW10V2V2-K 1X35mm² | Conductor conductor Construction (no/mm): 1121/0.2AS · Conductor Stranded Dia. (mm): 8.00 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 0.527 · Insulation Nominal Thickness (mm): 0.8/1.0 · Insulation MAX.Insulation Dia. (mm): 13.6 |
| ESW10V2V2-K 1X50mm² | Conductor conductor Construction (no/mm): 1596/0.2AS · Conductor Stranded Dia. (mm): 9.50 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 0.368 · Insulation Nominal Thickness (mm): 0.9/1.1 · Insulation MAX.Insulation Dia. (mm): 15.8 |
| ESW10V2V2-K 1X70mm² | Conductor conductor Construction (no/mm): 2257/0.2AS · Conductor Stranded Dia. (mm): 11.50 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 0.259 · Insulation Nominal Thickness (mm): 1.0/1.1 · Insulation MAX.Insulation Dia. (mm): 17.5 |
| ESW10V2V2-K 1X95mm² | Conductor conductor Construction (no/mm): 1887/0.25AS · Conductor Stranded Dia. (mm): 13.50 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 0.196 · Insulation Nominal Thickness (mm): 1.2/1.1 · Insulation MAX.Insulation Dia. (mm): 19.5 |
| ESW10V2V2-K 1X120mm² | Conductor conductor Construction (no/mm): 2368/0.254AS · Conductor Stranded Dia. (mm): 15.60 · Conductor 20℃ Conductor Max Resistance AT 20℃(Ω/km): 0.153 · Insulation Nominal Thickness (mm): 1.2/1.2 · Insulation MAX.Insulation Dia. (mm): 21.5 |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing