100℃ Hot-resistant Automobile Wire
100℃ Hot-resistant Automobile Wire. Rated temperature: 105℃ (Chinese text: 100℃). Rated voltage: 60V DC & 25V AC. According to: JASO D611. Stranded tinned or bare copper conductor 0.5-40mm². XLPVC insulation. Passes JASO D611 Vertical flame test. Application: Internal wiring of the car.
| AVX | (mm²) Cross Section (mm²): 0.5 · conductor Construction (no/mm): 7/0.32 · (mm) Conductor outer Diameter (mm): 0.96 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.2 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 34.5 · Standard pup-up METER/ROLL: 500 |
|---|---|
| AVX (2) | (mm²) Cross Section (mm²): 0.5f · conductor Construction (no/mm): 20/0.18 · (mm) Conductor outer Diameter (mm): 0.92 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.2 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 38.6 · Standard pup-up METER/ROLL: 500 |
| AVX (3) | (mm²) Cross Section (mm²): 0.75 · conductor Construction (no/mm): 30/0.18 · (mm) Conductor outer Diameter (mm): 1.13 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 25.7 · Standard pup-up METER/ROLL: 500 |
| AVX (4) | (mm²) Cross Section (mm²): 0.85 · conductor Construction (no/mm): 11/0.32 · (mm) Conductor outer Diameter (mm): 1.21 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 20.8 · Standard pup-up METER/ROLL: 500 |
| AVX (5) | (mm²) Cross Section (mm²): 0.85f · conductor Construction (no/mm): 35/0.18 · (mm) Conductor outer Diameter (mm): 1.23 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 20.53 · Standard pup-up METER/ROLL: 500 |
| AVX (6) | (mm²) Cross Section (mm²): 1 · conductor Construction (no/mm): 32/0.2 · (mm) Conductor outer Diameter (mm): 1.30 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 2.6 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 19.5 · Standard pup-up METER/ROLL: 500 |
| AVX (7) | (mm²) Cross Section (mm²): 1.25 · conductor Construction (no/mm): 16/0.32 · (mm) Conductor outer Diameter (mm): 1.47 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 2.9 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.3 · Standard pup-up METER/ROLL: 500 |
| AVX (8) | (mm²) Cross Section (mm²): 1.25 f · conductor Construction (no/mm): 50/0.18 · (mm) Conductor outer Diameter (mm): 1.47 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 2.9 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.7 · Standard pup-up METER/ROLL: 500 |
| AVX (9) | (mm²) Cross Section (mm²): 1.5 · conductor Construction (no/mm): 30/0.25 · (mm) Conductor outer Diameter (mm): 1.57 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 3.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 13.3 · Standard pup-up METER/ROLL: 500 |
| AVX (10) | (mm²) Cross Section (mm²): 2 · conductor Construction (no/mm): 26/0.32 · (mm) Conductor outer Diameter (mm): 2.06 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 3.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 8.81 · Standard pup-up METER/ROLL: 500 |
| AVX (11) | (mm²) Cross Section (mm²): 2.5 · conductor Construction (no/mm): 49/0.25 · (mm) Conductor outer Diameter (mm): 2.25 · (mm) Insulation Thickness (mm): 0.7 · (mm) Wire O.D (mm): 3.7 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 7.98 · Standard pup-up METER/ROLL: 300 |
| AVX (12) | (mm²) Cross Section (mm²): 3 · conductor Construction (no/mm): 41/0.32 · (mm) Conductor outer Diameter (mm): 2.62 · (mm) Insulation Thickness (mm): 0.7 · (mm) Wire O.D (mm): 4.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 5.59 · Standard pup-up METER/ROLL: 300 |
| AVX (13) | (mm²) Cross Section (mm²): 3f · conductor Construction (no/mm): 61/0.25 · (mm) Conductor outer Diameter (mm): 2.48 · (mm) Insulation Thickness (mm): 0.7 · (mm) Wire O.D (mm): 4.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 5.59 · Standard pup-up METER/ROLL: 300 |
| AVX (14) | (mm²) Cross Section (mm²): 5 · conductor Construction (no/mm): 65/0.32 · (mm) Conductor outer Diameter (mm): 3.29 · (mm) Insulation Thickness (mm): 0.8 · (mm) Wire O.D (mm): 4.9 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 3.52 · Standard pup-up METER/ROLL: 200 |
| AVX (15) | (mm²) Cross Section (mm²): 8 · conductor Construction (no/mm): 50/0.45 · (mm) Conductor outer Diameter (mm): 4.01 · (mm) Insulation Thickness (mm): 0.8 · (mm) Wire O.D (mm): 5.6 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 2.32 · Standard pup-up METER/ROLL: 200 |
| AVX (16) | (mm²) Cross Section (mm²): 15f · conductor Construction (no/mm): 171/0.32 · (mm) Conductor outer Diameter (mm): 5.3 · (mm) Insulation Thickness (mm): 1.1 · (mm) Wire O.D (mm): 7.5 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 1.37 · Standard pup-up METER/ROLL: 50 |
| AVX (17) | (mm²) Cross Section (mm²): 20f · conductor Construction (no/mm): 247/0.32 · (mm) Conductor outer Diameter (mm): 6.5 · (mm) Insulation Thickness (mm): 1.1 · (mm) Wire O.D (mm): 8.7 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 0.946 · Standard pup-up METER/ROLL: 50 |
| AVX (18) | (mm²) Cross Section (mm²): 30f · conductor Construction (no/mm): 361/0.32 · (mm) Conductor outer Diameter (mm): 7.8 · (mm) Insulation Thickness (mm): 1.4 · (mm) Wire O.D (mm): 10.6 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 0.473 · Standard pup-up METER/ROLL: 50 |
| AVX (19) | (mm²) Cross Section (mm²): 40f · conductor Construction (no/mm): 494/0.32 · (mm) Conductor outer Diameter (mm): 9.1 · (mm) Insulation Thickness (mm): 1.4 · (mm) Wire O.D (mm): 11.9 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 0.384 · Standard pup-up METER/ROLL: 50 |
| Standard | JASO D 611 |
| Construction | Single core: Conductor (stranded tinned or bare copper) + insulation (XLPVC) |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing