80℃ Automobile Wire with Thinner-wall Insulated
80℃ Automobile Wire with Thinner-wall Insulated. Rated temperature: 80℃. Rated voltage: 60V DC & 25V AC. According to: JASO D611. Stranded tinned or bare copper conductor 0.22-2mm². PVC insulation. Passes JASO D611 Vertical flame test. Application: Internal wiring of the car.
| AVSS | (mm²) Cross Section (mm²): 0.22 · conductor Construction (no/mm): 7/0.20 · (mm) Conductor outer Diameter (mm): 0.6 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.2 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 84.8 · Standard pup-up METER/ROLL: 500 |
|---|---|
| AVSS (2) | (mm²) Cross Section (mm²): 0.3 · conductor Construction (no/mm): 7/0.25 · (mm) Conductor outer Diameter (mm): 0.8 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 50.2 · Standard pup-up METER/ROLL: 500 |
| AVSS (3) | (mm²) Cross Section (mm²): 0.3f · conductor Construction (no/mm): 19/0.16 · (mm) Conductor outer Diameter (mm): 0.8 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 48.8 · Standard pup-up METER/ROLL: 500 |
| AVSS (4) | (mm²) Cross Section (mm²): 0.5f · conductor Construction (no/mm): 19/0.18 · (mm) Conductor outer Diameter (mm): 1.0 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.6 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 34.6 · Standard pup-up METER/ROLL: 500 |
| AVSS (5) | (mm²) Cross Section (mm²): 0.5 · conductor Construction (no/mm): 7/0.32 · (mm) Conductor outer Diameter (mm): 1.0 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.6 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 32.7 · Standard pup-up METER/ROLL: 500 |
| AVSS (6) | (mm²) Cross Section (mm²): 0.75f · conductor Construction (no/mm): 19/0.23 · (mm) Conductor outer Diameter (mm): 1.2 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.8 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 23.6 · Standard pup-up METER/ROLL: 500 |
| AVSS (7) | (mm²) Cross Section (mm²): 0.85 · conductor Construction (no/mm): 7/0.40 · (mm) Conductor outer Diameter (mm): 1.1 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 1.8 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 20.8 · Standard pup-up METER/ROLL: 500 |
| AVSS (8) | (mm²) Cross Section (mm²): 1.25 · conductor Construction (no/mm): 19/0.29 · (mm) Conductor outer Diameter (mm): 1.5 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 2.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.9 · Standard pup-up METER/ROLL: 500 |
| AVSS (9) | (mm²) Cross Section (mm²): 1.25f · conductor Construction (no/mm): 37/0.2 · (mm) Conductor outer Diameter (mm): 1.5 · (mm) Insulation Thickness (mm): 0.3 · (mm) Wire O.D (mm): 2.1 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.6 · Standard pup-up METER/ROLL: 500 |
| Standard | JASO D611 |
| AVSS (10) | (mm²) Cross Section (mm²): 2f · conductor Construction (no/mm): 37/0.25 · (mm) Conductor outer Diameter (mm): 1.8 · (mm) Insulation Thickness (mm): 0.4 · (mm) Wire O.D (mm): 2.6 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 9.5 · Standard pup-up METER/ROLL: 500 |
| AVSS (11) | (mm²) Cross Section (mm²): 2 · conductor Construction (no/mm): 19/0.37 · (mm) Conductor outer Diameter (mm): 1.9 · (mm) Insulation Thickness (mm): 0.4 · (mm) Wire O.D (mm): 2.7 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 9.0 · Standard pup-up METER/ROLL: 500 |
| Construction | Single core: Conductor (stranded tinned or bare copper) + insulation (PVC) |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing