Contact for Pricing
Volume pricing quoted per order.
80℃ Automobile Wire with Thin-wall Insulated
80℃ Automobile Wire with Thin-wall Insulated. Rated temperature: 80℃. Rated voltage: 60V DC & 25V AC. According to: JASO D611. Stranded tinned or bare copper conductor 0.3-8mm². PVC insulation. Passes JASO D611 Vertical flame test. Application: Internal wiring of the car.
| AVS | (mm²) Cross Section (mm²): 0.3 · conductor Construction (no/mm): 7/0.25 · (mm) Conductor outer Diameter (mm): 0.8 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 1.8 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 50.2 · Standard pup-up METER/ROLL: 500 |
|---|---|
| AVS (2) | (mm²) Cross Section (mm²): 0.3f · conductor Construction (no/mm): 15/0.18 · (mm) Conductor outer Diameter (mm): 0.8 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 1.8 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 48.9 · Standard pup-up METER/ROLL: 500 |
| AVS (3) | (mm²) Cross Section (mm²): 0.5f · conductor Construction (no/mm): 20/0.18 · (mm) Conductor outer Diameter (mm): 1.0 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.0 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 36.7 · Standard pup-up METER/ROLL: 500 |
| AVS (4) | (mm²) Cross Section (mm²): 0.5 · conductor Construction (no/mm): 7/0.32 · (mm) Conductor outer Diameter (mm): 1.0 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.0 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 32.7 · Standard pup-up METER/ROLL: 500 |
| AVS (5) | (mm²) Cross Section (mm²): 0.75f · conductor Construction (no/mm): 30/0.18 · (mm) Conductor outer Diameter (mm): 1.2 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.2 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 24.4 · Standard pup-up METER/ROLL: 500 |
| AVS (6) | (mm²) Cross Section (mm²): 0.85 · conductor Construction (no/mm): 16/0.25 · (mm) Conductor outer Diameter (mm): 1.2 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.2 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 22.0 · Standard pup-up METER/ROLL: 500 |
| AVS (7) | (mm²) Cross Section (mm²): 1.25f · conductor Construction (no/mm): 50/0.18 · (mm) Conductor outer Diameter (mm): 1.5 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.5 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.7 · Standard pup-up METER/ROLL: 500 |
| AVS (8) | (mm²) Cross Section (mm²): 1.25 · conductor Construction (no/mm): 16/0.32 · (mm) Conductor outer Diameter (mm): 1.5 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.5 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 14.3 · Standard pup-up METER/ROLL: 500 |
| AVS (9) | (mm²) Cross Section (mm²): 2f · conductor Construction (no/mm): 41/0.25 · (mm) Conductor outer Diameter (mm): 1.9 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.9 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 9.50 · Standard pup-up METER/ROLL: 500 |
| AVS (10) | (mm²) Cross Section (mm²): 2 · conductor Construction (no/mm): 26/0.32 · (mm) Conductor outer Diameter (mm): 1.9 · (mm) Insulation Thickness (mm): 0.5 · (mm) Wire O.D (mm): 2.9 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 8.81 · Standard pup-up METER/ROLL: 500 |
| AVS (11) | (mm²) Cross Section (mm²): 3f · conductor Construction (no/mm): 61/0.25 · (mm) Conductor outer Diameter (mm): 2.3 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 3.5 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 6.06 · Standard pup-up METER/ROLL: 300 |
| AVS (12) | (mm²) Cross Section (mm²): 3 · conductor Construction (no/mm): 41/0.32 · (mm) Conductor outer Diameter (mm): 2.4 · (mm) Insulation Thickness (mm): 0.6 · (mm) Wire O.D (mm): 3.7 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 5.59 · Standard pup-up METER/ROLL: 300 |
| AVS (13) | (mm²) Cross Section (mm²): 5 · conductor Construction (no/mm): 65/0.32 · (mm) Conductor outer Diameter (mm): 3.0 · (mm) Insulation Thickness (mm): 0.7 · (mm) Wire O.D (mm): 4.5 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 3.52 · Standard pup-up METER/ROLL: 300 |
| AVS (14) | (mm²) Cross Section (mm²): 5f · conductor Construction (no/mm): 7/30/0.18 · (mm) Conductor outer Diameter (mm): 3.4 · (mm) Insulation Thickness (mm): 0.7 · (mm) Wire O.D (mm): 5.0 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 3.56 · Standard pup-up METER/ROLL: 200 |
| AVS (15) | (mm²) Cross Section (mm²): 8 · conductor Construction (no/mm): 50/0.45 · (mm) Conductor outer Diameter (mm): 3.7 · (mm) Insulation Thickness (mm): 0.8 · (mm) Wire O.D (mm): 5.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 2.32 · Standard pup-up METER/ROLL: 200 |
| AVS (16) | (mm²) Cross Section (mm²): 8f · conductor Construction (no/mm): 7/22/0.25 · (mm) Conductor outer Diameter (mm): 3.7 · (mm) Insulation Thickness (mm): 0.8 · (mm) Wire O.D (mm): 5.4 · (Ω/km) Max Cond Resistance (Ω/km,20℃): 2.32 · Standard pup-up METER/ROLL: 200 |
| Standard | JASO D611 |
| Construction | Single core: Conductor (stranded tinned or bare copper) + insulation (PVC) |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing