Contact for Pricing
Volume pricing quoted per order.
500V PVC Jacket Wire
500V PVC JACKET WIRE. Rated temperature: 70℃. Rated voltage: 300/500V. According to: GB/T5023.5. Stranded tinned or bare copper conductor 0.75-2.5mm². PVC insulation and jacket. Passes GB/T18380.12 flame test. Application: Suitable for indoor electrical instruments power sipply wire (as printed; ).
| Standard | GB/T5023.5 |
|---|---|
| Construction | Stranded tinned or bare copper conductor 0.75-2.5mm², PVC insulation and PVC jacket; round or flat multi-core (2C-5C) jacketed cord |
| 60227 IEC 53(RVV) | WIRE TYPE (mm²): 0.75 · No.of Cores: 2C · Conductor size (No/mm): 24/0.2 · Core size (mm): 1.13 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.4 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 6.5 · Max Cond Resistance (Ω/km,20℃): 26.0 |
| 60227 IEC 53(RVV) (2) | WIRE TYPE (mm²): 0.75 · No.of Cores: 2C · Conductor size (No/mm): 24/0.2 · Core size (mm): 1.13 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.4 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 4.2×6.5 · Max Cond Resistance (Ω/km,20℃): 26.0 |
| 60227 IEC 53(RVV) (3) | WIRE TYPE (mm²): 0.75 · No.of Cores: 3C · Conductor size (No/mm): 24/0.2 · Core size (mm): 1.13 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.4 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 6.9 · Max Cond Resistance (Ω/km,20℃): 26.0 |
| 60227 IEC 53(RVV) (4) | WIRE TYPE (mm²): 0.75 · No.of Cores: 4C · Conductor size (No/mm): 24/0.2 · Core size (mm): 1.13 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.4 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 7.5 · Max Cond Resistance (Ω/km,20℃): 26.0 |
| 60227 IEC 53(RVV) (5) | WIRE TYPE (mm²): 0.75 · No.of Cores: 5C · Conductor size (No/mm): 24/0.2 · Core size (mm): 1.13 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.4 · JACKE-TS (mm): 0.9 · Jacket I.D. (mm): 8.5 · Max Cond Resistance (Ω/km,20℃): 26.0 |
| 60227 IEC 53(RVV) (6) | WIRE TYPE (mm²): 1.0 · No.of Cores: 2C · Conductor size (No/mm): 32/0.2 · Core size (mm): 1.3 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.6 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 6.9 · Max Cond Resistance (Ω/km,20℃): 19.5 |
| 60227 IEC 53(RVV) (7) | WIRE TYPE (mm²): 1.0 · No.of Cores: 2C · Conductor size (No/mm): 32/0.2 · Core size (mm): 1.3 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.6 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 4.3×6.9 · Max Cond Resistance (Ω/km,20℃): 19.5 |
| 60227 IEC 53(RVV) (8) | WIRE TYPE (mm²): 1.0 · No.of Cores: 3C · Conductor size (No/mm): 32/0.2 · Core size (mm): 1.3 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.6 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 7.4 · Max Cond Resistance (Ω/km,20℃): 19.5 |
| 60227 IEC 53(RVV) (9) | WIRE TYPE (mm²): 1.0 · No.of Cores: 4C · Conductor size (No/mm): 32/0.2 · Core size (mm): 1.3 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.6 · JACKE-TS (mm): 0.9 · Jacket I.D. (mm): 8.2 · Max Cond Resistance (Ω/km,20℃): 19.5 |
| 60227 IEC 53(RVV) (10) | WIRE TYPE (mm²): 1.0 · No.of Cores: 5C · Conductor size (No/mm): 32/0.2 · Core size (mm): 1.3 · Insulation Thickness (mm): 0.6 · Insulation I.D. (mm): 2.6 · JACKE-TS (mm): 0.9 · Jacket I.D. (mm): 9.0 · Max Cond Resistance (Ω/km,20℃): 19.5 |
| 60227 IEC 53(RVV) (11) | WIRE TYPE (mm²): 1.5 · No.of Cores: 2C · Conductor size (No/mm): 30/0.25 · Core size (mm): 1.58 · Insulation Thickness (mm): 0.7 · Insulation I.D. (mm): 3.1 · JACKE-TS (mm): 0.8 · Jacket I.D. (mm): 7.9 · Max Cond Resistance (Ω/km,20℃): 13.3 |
| 60227 IEC 53(RVV) (12) | WIRE TYPE (mm²): 1.5 · No.of Cores: 3C · Conductor size (No/mm): 30/0.25 · Core size (mm): 1.58 · Insulation Thickness (mm): 0.7 · Insulation I.D. (mm): 3.1 · JACKE-TS (mm): 0.9 · Jacket I.D. (mm): 8.6 · Max Cond Resistance (Ω/km,20℃): 13.3 |
| 60227 IEC 53(RVV) (13) | WIRE TYPE (mm²): 1.5 · No.of Cores: 4C · Conductor size (No/mm): 30/0.25 · Core size (mm): 1.58 · Insulation Thickness (mm): 0.7 · Insulation I.D. (mm): 3.1 · JACKE-TS (mm): 1.0 · Jacket I.D. (mm): 9.7 · Max Cond Resistance (Ω/km,20℃): 13.3 |
| 60227 IEC 53(RVV) (14) | WIRE TYPE (mm²): 1.5 · No.of Cores: 5C · Conductor size (No/mm): 30/0.25 · Core size (mm): 1.58 · Insulation Thickness (mm): 0.7 · Insulation I.D. (mm): 3.1 · JACKE-TS (mm): 1.1 · Jacket I.D. (mm): 10.8 · Max Cond Resistance (Ω/km,20℃): 13.3 |
| 60227 IEC 53(RVV) (15) | WIRE TYPE (mm²): 2.5 · No.of Cores: 2C · Conductor size (No/mm): 49/0.25 · Core size (mm): 2.02 · Insulation Thickness (mm): 0.8 · Insulation I.D. (mm): 3.7 · JACKE-TS (mm): 1.0 · Jacket I.D. (mm): 9.6 · Max Cond Resistance (Ω/km,20℃): 7.98 |
| 60227 IEC 53(RVV) (16) | WIRE TYPE (mm²): 2.5 · No.of Cores: 3C · Conductor size (No/mm): 49/0.25 · Core size (mm): 2.02 · Insulation Thickness (mm): 0.8 · Insulation I.D. (mm): 3.7 · JACKE-TS (mm): 1.1 · Jacket I.D. (mm): 10.5 · Max Cond Resistance (Ω/km,20℃): 7.98 |
| 60227 IEC 53(RVV) (17) | WIRE TYPE (mm²): 2.5 · No.of Cores: 4C · Conductor size (No/mm): 49/0.25 · Core size (mm): 2.02 · Insulation Thickness (mm): 0.8 · Insulation I.D. (mm): 3.7 · JACKE-TS (mm): 1.1 · Jacket I.D. (mm): 11.5 · Max Cond Resistance (Ω/km,20℃): 7.98 |
| 60227 IEC 53(RVV) (18) | WIRE TYPE (mm²): 2.5 · No.of Cores: 5C · Conductor size (No/mm): 49/0.25 · Core size (mm): 2.02 · Insulation Thickness (mm): 0.8 · Insulation I.D. (mm): 3.7 · JACKE-TS (mm): 1.2 · Jacket I.D. (mm): 12.8 · Max Cond Resistance (Ω/km,20℃): 7.98 |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing