750V PVC INSULATION WIRE. Rated temperature: 70℃. Rated voltage: 450/750V. According to: GB/T5023.3. Stranded tinned or bare copper conductor 1.5-25mm². PVC insulation. Passes GB/T18380.12 flame test. Application: Internal wiring of appliances or electronic equipment.
| Standard | GB/T5023.3 |
|---|---|
| Construction | Stranded tinned or bare copper conductor 1.5-25mm², single-core PVC insulation ( Conductor / insulation) |
| 60227 IEC 01(BV) | WIRE TYPE (mm²): 1.5 · Conductor size (No/mm): 30/0.25 · Core size (mm): 1.58 · Insulation Thickness (mm): 0.7 · I.D. (mm): 3.1 · Max Cond Resistance (Ω/km,20℃): 13.3 · STANDARD PUT-UP (M/COIL) ( / ): 500 |
| 60227 IEC 01(BV) (2) | WIRE TYPE (mm²): 2.5 · Conductor size (No/mm): 49/0.25 · Core size (mm): 2.02 · Insulation Thickness (mm): 0.8 · I.D. (mm): 3.8 · Max Cond Resistance (Ω/km,20℃): 7.98 · STANDARD PUT-UP (M/COIL) ( / ): 300 |
| 60227 IEC 01(BV) (3) | WIRE TYPE (mm²): 4.0 · Conductor size (No/mm): 56/0.3 · Core size (mm): 2.59 · Insulation Thickness (mm): 0.8 · I.D. (mm): 4.4 · Max Cond Resistance (Ω/km,20℃): 4.95 · STANDARD PUT-UP (M/COIL) ( / ): 300 |
| 60227 IEC 01(BV) (4) | WIRE TYPE (mm²): 6.0 · Conductor size (No/mm): 84/0.3 · Core size (mm): 3.17 · Insulation Thickness (mm): 0.8 · I.D. (mm): 5.0 · Max Cond Resistance (Ω/km,20℃): 3.3 · STANDARD PUT-UP (M/COIL) ( / ): 300 |
| 60227 IEC 01(BV) (5) | WIRE TYPE (mm²): 10 · Conductor size (No/mm): 84/0.4 · Core size (mm): 4.6 · Insulation Thickness (mm): 1.0 · I.D. (mm): 6.6 · Max Cond Resistance (Ω/km,20℃): 1.91 · STANDARD PUT-UP (M/COIL) ( / ): 200 |
| 60227 IEC 01(BV) (6) | WIRE TYPE (mm²): 16 · Conductor size (No/mm): 126/0.4 · Core size (mm): 5.7 · Insulation Thickness (mm): 1.0 · I.D. (mm): 7.7 · Max Cond Resistance (Ω/km,20℃): 1.21 · STANDARD PUT-UP (M/COIL) ( / ): 200 |
| 60227 IEC 01(BV) (7) | WIRE TYPE (mm²): 25 · Conductor size (No/mm): 196/0.4 · Core size (mm): 6.95 · Insulation Thickness (mm): 1.2 · I.D. (mm): 9.6 · Max Cond Resistance (Ω/km,20℃): 0.78 · STANDARD PUT-UP (M/COIL) ( / ): 100 |

USB Outlets, 15 Amp Wall Outlet with USB Ports, 21W USB Outlets Receptacles with Type A & Type C Ports, Tamper
15A
$9.00· each

ESW15Z3Z3-K Electric Cable (TÜV) For Battery Energy Storage System
Electric Cable (TÜV) For Battery Energy Storage System
Contact for Pricing

QBJ-C/D/E Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing

EV-YJ/SIR Connecting Cables for Battery Energy Storage Systems
Connecting Cables for Battery Energy Storage Systems
Contact for Pricing